B.44 Keithley SourceMeter 2600A and 2600B series
Module name: keithley2600a
This module can be compiled to support each of the devices from the 2600A and 2600N series of Keithley SourceMeters, i.e. 2601A, 2601B, 2602A, 2602B, 2611A, 2611B, 2612A, 2612B, 2614B, 2634B, 2635A, 2635B, 2636A and 2636B. See the configuration file for this module, it controls for which type of device the module gets compiled.
Controlled via: LAN (VXI-11 protocol), IP address must be set in the configuration file for the module.
Note: The number of points that can be done in measure-sweeps is limited to 728 or 2549 when measuring either voltage, current, power or resistance and to 364 or 1274 when measuring voltage and current simultaneously( the lower numbers are for ASCII data transfers, the higher for bianary transfers). This isn't due to some documented restriction but the result of the observation that reads from the output queue start to fail when it contains more than 10200 bytes. Each measured point can use up to 14 bytes with ASCII data tranfer and take 4 bytes with binary transfers, and the above maximum numbers are chosen to make sure the size of the output queue never exceeds those 10200 bytes.
Supported functions:
- `sourcemeter_name()'
- `sourcemeter_keep_on_at_end()'
- `sourcemeter_reset_on_start()'
- `sourcemeter_reset()'
- `sourcemeter_sense_mode()'
- `sourcemeter_source_offmode()'
- `sourcemeter_output_state()'
- `sourcemeter_source_mode()'
- `sourcemeter_source_voltage()'
- `sourcemeter_source_current()'
- `sourcemeter_source_voltage_range()'
- `sourcemeter_source_current_range()'
- `sourcemeter_source_voltage_autoranging()'
- `sourcemeter_source_current_autoranging()'
- `sourcemeter_source_voltage_autorange_low_limit()'
- `sourcemeter_source_current_autorange_low_limit()'
- `sourcemeter_compliance_voltage()'
- `sourcemeter_compliance_current()'
- `sourcemeter_test_compliance()'
- `sourcemeter_source_delay()'
- `sourcemeter_source_max_off_current()'
- `sourcemeter_source_high_capacity()'
- `sourcemeter_source_sink_mode()'
- `sourcemeter_source_settling_mode()'
- `sourcemeter_measure_voltage()'
- `sourcemeter_measure_current()'
- `sourcemeter_measure_power()'
- `sourcemeter_measure_resistance()'
- `sourcemeter_measure_voltage_and_current()'
- `sourcemeter_measure_voltage_autoranging()'
- `sourcemeter_measure_current_autoranging()'
- `sourcemeter_measure_voltage_range()'
- `sourcemeter_measure_current_range()'
- `sourcemeter_measure_voltage_autorange_low_limit()'
- `sourcemeter_measure_current_autorange_low_limit()'
- `sourcemeter_measure_delay()'
- `sourcemeter_measure_time()'
- `sourcemeter_measure_voltage_offset()'
- `sourcemeter_measure_current_offset()'
- `sourcemeter_measure_filter_type()'
- `sourcemeter_measure_filter_count()'
- `sourcemeter_sweep_voltage_measure_voltage'
- `sourcemeter_sweep_voltage_measure_current'
- `sourcemeter_sweep_voltage_measure_power'
- `sourcemeter_sweep_voltage_measure_resistance'
- `sourcemeter_sweep_voltage_measure_voltage_and_current'
- `sourcemeter_sweep_current_measure_voltage'
- `sourcemeter_sweep_current_measure_current'
- `sourcemeter_sweep_current_measure_power'
- `sourcemeter_sweep_current_measure_resistance'
- `sourcemeter_sweep_current_measure_voltage_and_current'
- `sourcemeter_list_sweep_voltage_measure_voltage'
- `sourcemeter_list_sweep_voltage_measure_current'
- `sourcemeter_list_sweep_voltage_measure_power'
- `sourcemeter_list_sweep_voltage_measure_resistance'
- `sourcemeter_list_sweep_voltage_measure_voltage_and_current'
- `sourcemeter_list_sweep_current_measure_voltage'
- `sourcemeter_list_sweep_current_measure_current'
- `sourcemeter_list_sweep_current_measure_power'
- `sourcemeter_list_sweep_current_measure_resistance'
- `sourcemeter_list_sweep_current_measure_voltage_and_current'
- `sourcemeter_contact_check()'
- `sourcemeter_contact_resistance()'
- `sourcemeter_contact_threshold()'
- `sourcemeter_contact_speed()'